Skip to main content

Profitec Pro 400: Bulb Filter Inspection

The in-line bulb filter between the reservoir and the pump can cause a low flow condition and force the pump to struggle.

Tools Needed:
- 3mm Allen wrench or hex driver
- Replacement bulb filter
- Towel
​
1. Start by draining the machine. Then unplug the machine and allow it to cool.
​
2. Tilt the machine up onto its front, carefully resting it on the group head. You may want to place a towel under the machine or group head to prevent marring the finish.
(There is no need to remove the side panels at this time.)
​

Pro400_heating_element_79


​
3. Locate the access panel on the underside of the machine and remove it by unscrewing the four 3mm Allen head screws as indicated.
​

Pro400_heating_element_80-1


​
4. Identify the bulb filter.
NOTE: The fine mesh filter inside the bulb can become clogged or worn with age in a manner that is not obvious. It is not possible to verify the condition of the bulb filter from visual inspection alone.
​

Pro400_bulb_filter_03


​
5. Disconnect the bulb filter from the silicone tubing attached to either end, then remove from machine.
​

Pro400_bulb_filter_04


(When re-installing, note that the yellow dot should be oriented toward the pump as shown here.)
​
6. Flush the bulb filter with water and/or blow compressed air into the bulb filter to clear away any built-up debris or mineral deposits. Replace with a new filter if necessary.
​
7. Re-install the bulb filter by following these steps in reverse.

Did this answer your question?