Tools Needed:
- Adjustable wrench
- Shop towel
- Pick or small prying implement
- New gasket, ECM/Profitec part P6015

1. Remove the steam/hot water valve assembly.

2. Use a large adjustable wrench to remove the wand arm ball joint nut. Drape a towel over the fitting to protect the finish.

Pro600_ball_joint_gasket_01


Pro600_ball_joint_gasket_02-1



3. Be careful not to lose the tensioner spring between the ball joint and steam valve outlet. Take note of its proper orientation for reassembly.

Pro600_ball_joint_gasket_03



4. Use a pick or small prying implement to remove the old gasket. Install the new gasket.

Pro600_ball_joint_gasket_04



5. It may be handy to have a helper hold the machine steady while you use both hands to reassemble the ball joint nut against the tension of the spring. Start the nut by hand first, then tighten with the wrench.