Maintenance and Repair

Lelit Mara X: Removing the Panels

Use these instructions to remove the panels from your Mara X for maintenance or repair.

Tools Needed:
- #2 Philips screwdriver

NOTE: The machine should be unplugged and cool to the touch before you begin.

1. Start by removing the drip tray, cup tray and reservoir.
IMG_8044-1

2. Remove the eight Philips head screws from the top panel shown here. Remove the top panel and set it aside.
IMG_8046
IMG_8047

- Stop here and reinstall the reservoir if all you need is access through the top. -

3. Remove the remaining screws from the top of each side of the wrap around side panel.
IMG_8062-1

4. Remove the screws from the bottom corner of each side of the wrap around side panel.
IMG_8061
IMG_8060-1

5. Remove the single screw in the bottom middle of the back side of the wrap around panel.
IMG_8063-1


6. You can now gently pry the panels outward in front and pull the wrap around panel straight back to remove it from the machine.
IMG_8064


To complete the full panel removal process, continue through to the following guides:
Lelit Mara X: Disassembling the Reservoir Tray
Lelit Mara X: Accessing the Underside of the Machine