LUCCA A53 Mini / Mini Vivaldi: Cleaning Fill Probe (Steam Boiler Overfilling)

Below are photo instructions for cleaning a fill probe and fill probe fittings on your La Spaziale LUCCA A53 Mini or Mini Vivaldi espresso machine. Checking and cleaning the fill probe is helpful to stop a steam boiler from overfilling.

In order to fully access the fill probe it is helpful to remove the side panels. When doing this be sure that the machine is unplugged and not heated.

Tools needed:

  • small flat head screwdriver
  • 12mm wrench(or adjustable wrench)
  • wire brush/steel wool

 