Skip to main content

ECM Mechanika V Slim: Steam Pressure Gauge Replacement

If your steam pressure gauge is unresponsive, leaking, or building condensation, you may need to replace it! Here's how

What you'll need:

- 13mm wrench

- (2) 14mm wrench(es)

Before diving in, you'll need to Remove the Top Panel.
​
Locate the steam pressure gauge on the front left side of the machine.
​

ECM-Mechanika-Gauge-View


​
Place one 14mm wrench on the square fixture on the gauge (inside the bracket) and the 13mm wrench on the capillary tube nut
​

ECM-Mechanika-Steam-Pressure-Gauge-Capillary-tube-Wrench


​
Squeezing the two wrenches together, you'll loosen the capillary tube nut enough that you can unthread it the rest of the way using your fingers.

ECM-Mechanika-Steam-Pressure-Gauge-Capillary-Tube-Wrench-Movement


​

ECM-Mechanika-Steam-Pressure-Gauge-Capillary-Tube-removal


​
Place one 14mm wrench back on that square piece, and the other 14mm wrench on the nut fastening the bracket to the machine.
​

ECM-Mechanika-Steam-Pressure-Gauge-Bracket-Nut-Placement


​
Similarly, squeeze the two wrenches (or hold the one on the square nut steady), and loosen the bracket nut.

ECM-Mechanika-Steam-Pressure-Gauge-Bracket-Nut


​
Remove the nut, and pull the bracket from the gauge.
​

ECM-Mechanika-Steam-Pressure-Gauge-Bracket


​
Remove the gauge through the front of the machine.
​

ECM-Mechanika-Steam-Pressure-Gauge-Removal


​
​
​
To replace, insert the new gauge through the front and follow these steps in reverse order. If you need further assistance, contact us at [email protected]