What you'll need:

- 13mm wrench

- (2) 14mm wrench(es)

Before diving in, you'll need to Remove the Top Panel.

Locate the steam pressure gauge on the front left side of the machine.

ECM-Mechanika-Gauge-View



Place one 14mm wrench on the square fixture on the gauge (inside the bracket) and the 13mm wrench on the capillary tube nut

ECM-Mechanika-Steam-Pressure-Gauge-Capillary-tube-Wrench



Squeezing the two wrenches together, you'll loosen the capillary tube nut enough that you can unthread it the rest of the way using your fingers.

ECM-Mechanika-Steam-Pressure-Gauge-Capillary-Tube-Wrench-Movement


ECM-Mechanika-Steam-Pressure-Gauge-Capillary-Tube-removal



Place one 14mm wrench back on that square piece, and the other 14mm wrench on the nut fastening the bracket to the machine.

ECM-Mechanika-Steam-Pressure-Gauge-Bracket-Nut-Placement



Similarly, squeeze the two wrenches (or hold the one on the square nut steady), and loosen the bracket nut.

ECM-Mechanika-Steam-Pressure-Gauge-Bracket-Nut



Remove the nut, and pull the bracket from the gauge.

ECM-Mechanika-Steam-Pressure-Gauge-Bracket



Remove the gauge through the front of the machine.

ECM-Mechanika-Steam-Pressure-Gauge-Removal





To replace, insert the new gauge through the front and follow these steps in reverse order. If you need further assistance, contact us at [email protected]