Tools Needed:

  • 2.5mm Allen key

  • Adjustable wrench

1. Turn the machine off, unplug it and allow it to fully cool down.

2. Remove the panels of the Synchronika: ECM Synchronika Panel Removal Instructions

3. Remove the capillary tube from the back of the gauge.

ECM Synchronika Espresso Machine: Gauge Replacement

4. Remove the collar from the gauge threads which will free the bracket up, you can take the gauge out of the front of the machine now.

ECM Synchronika Espresso Machine: Gauge Replacement

5. Install the new gauge from the front and put the bracket on the backside of it.

6. Tighten down the bracket with the collar.

ECM Synchronika Espresso Machine: Gauge Replacement

7. Reattach the capillary tube. DO NOT OVERTIGHTEN. Capillary tubes are malleable and can break if tightened too much.

ECM Synchronika Espresso Machine: Gauge Replacement

8. Test the machine with the panels removed to check for leaks, tighten capillary tube fitting as needed.