Skip to main content

Rancilio Silvia Pro/Pro X: Steam boiler Temperature Probe Cleaning/Replacement

This article shows how to remove and clean the temperature probe on the steam boiler of a Silvia Pro or Pro X.

Tools Needed:
​

  • Phillips head screwdriver

  • 17mm crescent wrench

  • Scouring pad or wire brush

  • Urnex or espresso cleaning solution

  • PTFE tape

  • Towel (to catch spills)

  • Replacement Temperature Probe (if necessary)


​

Begin with your machine unplugged and fully cooled/depressurized.

1. Remove the panels from your Silvia Pro or Pro X. You will also need to remove the reservoir holder by removing the 2 screws and unplugging the 2 leads.
​
​

20231024_171736


​

1000003837-1


​
2. Before removing the temperature probe from the steam boiler, you will need to finish draining the boiler manually.
​
​

1000003850


​
3. Locate the temperature probe and disconnect the wiring harness. You may need to remove the zip-tie for better access.
​
​

1000003855-1


​

1000003856


​

1000003857

4. Use the 17mm wrench to remove the temperature probe from the brew boiler. (You may want to place a towel underneath, as a small amount of water may still be in the boiler)
​
​

1000003858


​
5. Inspect the probe for signs of scale and clean using a mixture of Urnex and hot water and a scotch brite pad. Replace with a new temperature probe if necessary, and wrap the threads with PTFE tape.
​
​

1000003859


​
6) Follow these directions in reverse to reinstall the probe. Don't forget to reattach the wiring harness!

Did this answer your question?