Skip to main content

Bezzera BZ10: Cleaning the 3-Way Solenoid Valve

Imported from HubSpot KB export -- 2026-08-14

Z
Written by Zac P

Tools needed:

- 12mm crescent wrench

- 14mm crescent wrench

- 16mm crescent wrench

- 22mm crescent wrench

- optional: table vice

Make sure the machine is off, unplugged, and cooled down.

2. Locate the 3-way solenoid valve on the right hand side of the boiler:

IMG_0115

3. Remove the electrical leads from the solenoid box:

IMG_0117

4. Using a 16mm crescent wrench, unscrew the capillary tube from the solenoid valve assembly and carefully push to the side:

IMG_0116

5. Using the 12mm wrench, remove the silicon tube from the adapter attached to the solenoid box:

IMG_0118

6. Remove the adapter from the solenoid box with the 14mm wrench:

IMG_0119

7. Use a 14mm wrench to remove the retaining nut and the solenoid box should slide right off:

IMG_0121

8. From here you can use the 22mm wrench to remove the armature from the assembly (make sure the copper tubing attached to the assembly does not become twisted):

IMG_0122-1

Alternative option: With the 16mm wrench, loosen the nuts that attached the copper tubing to the valve assembly:

IMG_0124-2

and use a table vice to hold the valve assembly while removing the armature:

IMG_0128

9. Inspect and clean the inside of the valve body and the armature then make sure the spring moves freely before reinstalling.

IMG_0129

10. Reassemble the solenoid by following these steps in reverse order.

Did this answer your question?