Tools Needed:

  • Phillips Screwdriver

  • 14mm Wrench

  • 22mm Wrench

  • Adjustable Wrench
    (You can use two adjustable wrenches if you don't have a set of metric wrenches.)

1. Remove the panels of the machine.

2. Unscrew the retaining nut holding the solenoid coil in place using a 14mm wrench.

LUCCA A53 / Vivaldi: Cleaning Fill Solenoid

You can then slide the solenoid coil (black box) off of the solenoid armature (steel shaft). Keep track of any washers that come off along with the solenoid coil.

3. Unscrew the solenoid armature using the 22mm wrench.

LUCCA A53 / Vivaldi: Cleaning Fill Solenoid


You will need to use the adjustable wrench to hold the valve body so you don't bend the copper connecting tube.

LUCCA A53 / Vivaldi: Cleaning Fill Solenoid

4. Make sure there is no debris or build-up inside the brass valve body. Then verify that the black rubber seal on the plunger is clean and in good condition.

LUCCA A53 / Vivaldi: Cleaning Fill Solenoid

5. Remove the plunger from the solenoid armature and make sure it's clean and free of debris.

IMG_6246



IMG_6247


Make sure that the inside of the armature is also clean:

IMG_6248


6. Make sure that the plunger moves smoothly up and down inside the armature before reassembling.

IMG_6249