Tools needed:

- 16mm crescent wrench

- bucket or sink

- 2-4 hands

2. Locate the copper tube that attaches to both the boiler and the steam valve:

IMG_0130

2. Remove the copper tubing from both sides:

IMG_0104-1
IMG_0131

3. Flip the tubing around like so:

IMG_0132
IMG_0133

4. At this point you can either carefully bend the copper tubing to a right angle or place a small towel under the tubing to protect the inner components:

IMG_0134
IMG_0143-1

5. Open the hot water valve to introduce air into the system:

IMG_0135-1

6. Please use caution for this next step! Pull your machine forward to the end of the bench or counter and tilt it over a bucket or a sink so that the water can drain from the boiler:

IMG_0142-1

You have successfully drained the boiler of your BZ10!