Group Head & Brew Boiler Maintenance
  1. Help Center
  2. LUCCA M58 by Quick Mill
  3. Group Head & Brew Boiler Maintenance

Lucca M58: Adjusting Pump Pressure

How to adjust the pump pressure. (Difficulty ☕)

Tools Needed:

  • Flathead screwdriver
  • Backflush Blank

1. Locate and remove the small rubber cap from the right-hand side of the machine.

IMG_3157

2. With the back flush disc inserted, engage the brew lever and turn the small screw in \side the machine until the pump pressure gauge reads 8.5-10 bars. (Clockwise will increase, Counter-Clockwise will decrease)

IMG_3158

IMG_3159

3. Once you are satisfied with the brewing pressure, replace the black cap and enjoy!