PID Settings and Clive Recommended Settings

The advanced PID settings on an espresso machine allow you to modify operating parameters such as temperature offset and can be a handy tool if you are looking to make subtle changes to the way your machine maintains temperature.

To enter the advanced PID settings mode on the PID of any machine Clive offers:

  1. Turn your machine off
  2. Hold down BOTH the left and right button on the PID at the same time
  3. While both PID buttons are pressed down, turn the machine on and wait for "F.01" to appear

From here, you are in advanced PID settings mode. You can change your machine to function in Celsius or Fahrenheit, switch between 15 and 20 amp power modes (on applicable machines), change boiler temperature offset, and adjust boiler temperature.

To change a setting, press the left button on the PID until the setting you wish to change is showing. Press the right button on the PID to view that setting's current value, and while the current value is shown press the right and left buttons to adjust it up and down. To exit advanced PID settings mode and save your settings, simply turn the machine off and back on again.

We have done extensive testing to ensure the best performance out of each machine, taking into account temperature, reheating and amperage. Clive does not recommend changing of the P, I, D, or b settings on any of the machines. Changing those 4 settings will change the way the machines reheat and maintain temperature.

The settings that we recommend changing if you are looking for something a little different are:

  • The setting for which temperature scale you would like to use, commonly shown in the PID settings as F.01. - C (celsius), and F (Fahrenheit)
  • The setting to change your machine for running in 15 amp or 20 amp mode (on applicable machines). This setting is commonly shown as F.02
  • The setting to change the temperature of the coffee boiler, commonly shown in the PID settings as T1.
  • The setting to change the temperature of the steam boiler, commonly shown in the PID settings as T2.

NOTE: We do not recommend changing P, I, D or b settings. These change the algorithms for reheating and maintaining boiler temperature.

The Clive recommended settings for espresso machines we offer are as follows:

Lelit Bianca: 

KPc: 0.8, Klc:0.04, KDc:12.0, Bc: 15, KPs: 20.0, Kls: 0.00, KDs: 20.0, Bs: 0, Ec: 10, Es: 0, TR: 0

Quick Mill Lucca X58:

F.01: F, F.02: 3, P1: 1.5, I1: 0.00, D1: 1.5, b1: 10, P2: 1.5, I2: 0.00, D2: 1.5, b2: 6, T1: 201, T2: 255, E1: 27, E2: 0, nrG: no

Quick Mill Lucca M58 V1 (pre-2020):

F.01: F, F.02: 4, P1: 1.5, I1: 0.05, D1: 1.5, b1: 10, P2: 1.5, I2: 0.00, D2: 1.5, b2: 6, T1: 202, T2: 260, E1: 26, E2: 0 - The F.02 setting on the M58 when set to 4 will put the machine in 15 amp mode. If F.02 is changed to 6, the machine will run in 20 amp mode.*

*Only available on the V1 model M58.


Quick Mill Lucca M58 V2 (post-2020):

F.01: F, F.02: 4, P1: 0.7, I1: 0.00, D1: 3.5, b1: 22, P2: 1.0, I2: 0.80, D2: 4.0, b2: 6, T1: 202, T2: 260, E1: 26, E2: 0 

Profitec Pro 700 and ECM Synchronika:

F.01: F, F.02: 7, P: 2.5, I: 0.02, D: 8.0, Cln: 0, T1: 201, T2: 255, T3: 200, E1: 26, E2: 0, E3: 0 - The F.02 setting on the Pro 700 and Synchronika when set to 7 will put the machine in 15 amp mode. When set to 5, the machine will be in 20 amp mode.

Profitec Pro 700 and ECM Synchronika Updated Settings (post-2019):

F.01: F, F.02: 7, FIL: 0, P1: 2.5, I1: 0.02, d1: 8.0, b1: 10, P2: 17.5, I2: 0.09, d2: 25.0, b2: 2, P3: 2.5, I3: 0.02, d3: 8.0, b3: 10, Cln: 0, T1: 201, T2: 265, T3: 200, E1: 27, E2: 0, E3: 0, L1: 0, L2: 0, L: 0, o2: on, Eco: off

Profitec Pro 300:

F.01: F, P: 1.5, I: 0.01, D: 11.0, b: 40, T1: 201, E1: 24

Profitec Pro 500:

F.01: F, P: 17.5, I: 0.10, D: 25.0, T1: 255, E1: 0

Profitec Pro 600:

F.01: F, F.02: 7, FIL: 0, P1: 2.5, I1: 0.02, D1: 8.0, B1: 10, P.2: 17.5, I2: 0.09, D2 :25.0, B2: 2, P3: 2.5, I3: 0.02, D3: 8.0, B3: 10, T1:201, T2: 260, T3: 260, E1: 25, E2: 0, E3: 0


Profitec 600 With Quick Steam:
F.01: F, F.02: 7, FIL: 0, P1: 2.5, I1: 0.02, D1: 8.0, B1: 40, P.2: 17.5, I2: 0.09, D2 :25.0, B2: 2, CLN: 0, T1: 200, T2: 270, E1:31, o2: on, ECO: off, tUP: 266, sUP: 270, FH: on

Profitec Pro 800:

F.01: F, P.: 10.0, I.: 0.10, d.: 0.5, T1: 248, E1: 0

ECM Classika:

F.01: F, FIL: 0, CP: 2.5, CI: 0.16, Cd: 8.0, Cb: 40, Sp: 2.5, SI: 0.02, Sd: 8.0, Sb: 40, T1: 201, St: 260, E1: 17, E2: 0